Work

Simultaneous Observation of Motion and Size of a Sonoluminescing Bubble

Year: 2002
Type: article
Abstract: This paper describes a method of simultaneously executing both observations using a charge-coupled device (CCD) camera with stroboscopic light and measurement of bubble radius with light scattering. This optical system consists of a beam splitter inserted between a lens and the CCD camera, and a photomultiplier tube (PMT) mounted at the beam splitter. It is confirmed that this system is useful for the simultaneous observation of the bubble size, shape and translational motion.
Language: English
Open Access status: bronze
OpenAlex ID: W1990432409
FWCI: 4.359
Cites: 8
Cited by: 21
Related to: 9