Inherent design features of the GCFR
Year: 1980
Type: article
Abstract: This paper discusses several inherent design features of the GCFR that enhance its safety and presents analyses to demonstrate the degree of protection they provide. These features are a subset of a larger group of potential inherent features that form the third line of protection (LOP-3) for the GCFR. The function of LOP-3 is to demonstrate that the inherent response of the reactor system will limit core damage even if active cooling and shutdown systems in LOP-1 and LOP-2 fail. By providing this function with inherent features, which do not depend on active components and are self-controlling, an additional level of protection against common cause failure mechanisms is provided for both protected and unprotected events. The examples of LOP-3 discussed in this paper are natural circulation core cooling to the ultimate atmospheric heat sink and inherent reactor shutdown mechanisms.
Authors: W. Medwid, W. Breher, A.S. SHENOY, Ryan Elliott
Language: English
Subfield: Nuclear Energy and Engineering
Field: Energy
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W41710625