Study design: Observational Study
Abstract: COVID-19 has killed over 6 million people worldwide. Currently available methods to detect SARS-CoV-2 are limited by their cost and need for multistep sample preparation and trained personnel. Therefore, there is an urgent need to develop fast, inexpensive, and scalable point-of-care diagnostics that can be used for mass testing. Between January and March 2021, we obtained 321 anterior nare swab samples from individuals in Philadelphia (PA, USA). For the Real-time Accurate Portable Impedimetric Detection prototype 1.0 (RAPID) test, anterior nare samples were tested via an electrochemical impedance spectroscopy (EIS) approach. The overall sensitivity, specificity, and accuracy of RAPID in this cohort study were 80.6%, 89.0%, and 88.2%, respectively. We present a rapid, accurate, inexpensive (<$5.00 per unit), and scalable test for diagnosing COVID-19 at the point-of-care. We anticipate that further iterations of this approach will enable widespread deployment, large-scale testing, and population-level surveillance.
Source: iScience
Language: English
Subfield: Infectious Diseases
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $3,000
Funders: University of Pennsylvania, ACE Foundation, National Institutes of Health, Defense Threat Reduction Agency, Perelman School of Medicine, University of Pennsylvania, National Institute of General Medical Sciences, Institute for Diabetes, Obesity and Metabolism, Perelman School of Medicine, University of Pennsylvania
OpenAlex ID: W4220796897