Green Phosphorene as a Promising Biosensor for Detection of Furan and p-Xylene as Biomarkers of Disease: A DFT Study
Year: 2022
Type: article
Abstract: In this work, Green Phosphorene (GP) monolayers are studied as an electronic sensing element for detecting prostate cancer biomarkers from human urine. The adsorption of furan, C8H10 (p-xylene), and H2O on pristine GP and S- and Si-doped GP are investigated using the density functional theory (DFT) calculation. Furan and C8H10 molecules have been considered as important biomarkers of prostate cancer patients. First-principles DFT calculations are applied, and the results divulged that pristine GP could be a promising candidate for furan and C8H10 detection. It is manifested that furan and C8H10 are physisorbed on the S-, and Si-doped GP with small adsorption energy and negligible charge transfer. However, the calculations disclose that furan and C8H10 are chemically adsorbed on the pristine GP with adsorption energy of −0.73, and −1.46 eV, respectively. Moreover, we observe that a large charge is transferred from furan to the pristine GP with amount of −0.106 e. Additionally, pristine GP shows short recovery time of 1.81 s at room temperature under the visible light, which make it a reusable sensor device. Overall, our findings propose that the pristine GP sensor is a remarkable candidate for sensing of furan and other biomarkers of prostate cancer in the urine of patients.
Source: Sensors
DOI: 10.3390/s22093178
Institutions: Worcester Polytechnic Institute, Boston University
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $2,513
OpenAlex ID: W4224318749