Abstract: One of the more significant issues related to carbon capture retrofits pertains to the reduction in net power output (derate) due to the large parasitic power load required for appreciable levels of carbon capture. Post-combustion capture (PCC) has been shown to reduce the net plant efficiency of an equivalent plant without capture by 20 percent or more. Yet, post-combustion amine scrubbing is anticipated to be the most viable near-term technology for reducing carbon dioxide (CO2) emissions from existing coal plants. This study attempts to quantify auxiliary load replacement options for existing pulverized coal (PC) boilers to reduce the effects caused by steam and power requirements of the CCS systems and the resulting derated output of the existing plant. While individual retrofit options are highly plant-specific and, therefore, subject to unique optimization pathways, each of the proposed cases in this study attempts to examine the most promising configurations for each repowering technology.