Year: 1991
Type: article
Abstract: difficult to recognise, particularly in the pre-oxygenated patient.An unrecognised blind oesophageal intubation is surely in most instances more dangerous than a known failed tracheal intubation.The old adage is well worth repeating that patients do not die from failure to intubate but from failure to oxygenate.One point raised by the authors with which I can wholeheartedly agree is that anaesthetists faced with a difficult or failed intubation, in a patient not at risk of aspiration, should try the technique described, being sure to report failures as well as successes; reporting bias can be an enemy of such correspondence.I should say that I am firmly in favour of developing and practising techniques to aid intubation (gum elastic bougie, blind-nasal intubation fibreoptic intubation and indeed the new method described by the authors of the paper concerned), but I feel that until the value of the method is established in cases of difficult or failed intubation, it should not be recommended for use in these circumstances particularly in patients at risk of regurgitation as part of a failed intubation drill.So far, all the authors have described is a technique for tracheal intubation of routine cases that is less successful than the established method using a Macintosh laryngoscope.
Source: Anaesthesia
Authors: M.L. Heath, J. Allagain
Institution: University Hospital Lewisham
Language: English
Subfield: Anesthesiology and Pain Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: bronze
OpenAlex ID: W4240365026