Work

Health hazard evaluation report: HETA-89-270-2080, Harrisburg Steam Generation Facility, Harrisburg, Pennsylvania.

Year: 1990
Type: report
Abstract: In June 1989, the National Institute for Occupational Safety and Health (NIOSH) received a request from the City of Harrisburg to conduct a health hazard evaluation at the City's Steam Generation Facility.This facility incinerates municipal refuse to generate electricity.The request concerned potential exposures to fly ash, combustion products, and asbestos.On July 11-12, 1989, an initial "walkthrough" site visit was made.On October 24-26, 1989, a follow-up visit was made for the purpose of conducting environmental monitoring for total and respirable particulates, trace metals, crystalline silica, and asbestos.Bulk samples of ash, insulation, and settled dust were collected.Surface wipe samples were obtained to assess potential surface contamination with metals.The environmental data obtained by NIOSH investigators indicates the potential for high total particulate exposures (fly ash) for employees working in the boiler and basement areas, including the boiler fireman and laborers.Total particulate exposures ranging from 5 to 11 milligrams per cubic meter (mg/m 3 ) were obtained on the laborers.Although the personal breathing zone (PBZ) air concentrations of aluminum, cadmium, chromium, iron, and nickel were below existing guidelines and standards established by NIOSH and OSHA, the concentration of lead in three of the PBZ air samples exceeded the OSHA PEL of 0.05 mg/m 3 as an 8-hour time-weighted average (TWA) or 0.03 mg/m 3 as a 12-hour TWA.Air samples obtained on the boiler fireman and two laborers indicated airborne concentrations of 0.09, 0.09, and 0.14 mg/m 3 , respectively.NIOSH recommends that lead exposures be kept below 0.10 mg/m 3 .Crystalline silica was not detected in any of the PBZ air samples analyzed.Amosite and chrysotile asbestos were identified in bulk samples of insulation and chrysotile asbestos was present in a settled dust sample obtained in the boiler area.The poor condition of some of the insulation coverings and the presence of asbestos in settled dust samples, as well as in loose insulation samples obtained from the floor, indicates the potential for inhalation of asbestos fibers and the need for further evaluation and abatement.Surface wipe samples indicate a potential for hand-mouth contact with fly ash, particularly from surfaces in the break and locker room.The environmental data obtained at HSGF indicate a need for reducing worker exposures to fly ash particulates, as lead overexposures and high total particulate concentrations were measured for the boiler fireman and laborers.Recommendations for reducing particulate exposures through the use of engineering and work practice controls are made in the Recommendations Section of this report.Recommendations are also made to increase cleaning and maintenance activities, and to further evaluate asbestos contamination at this facility.
Language: English
Field: Medicine
Open Access status: gold
OpenAlex ID: W4243200669
Cites: 11
Cited by: 1
Related to: 10