Spherocytes flow behaviours in microrestriction, compared by normal red blood cells of different heat treatment levels
Year: 2021
Type: conference-paper
Abstract: Red blood cell (RBC) microfluidic flow behaviours could be altered by varies of factors: the density of RBC, the cell composition, the level of cell dehydration as well as the RBC membrane damage. For the electrical monitoring of RBC microfluidic flow behaviours, the contact surface between RBC and mimetic microrestriction wall, whose width is smaller than the RBC diameter, is crucial. In this paper, we focus on cell rigidity and morphological alterations induced by hereditary spherocytosis, which play an important role for the analysis of RBC flow behaviours and the discrimination between RBCs of different pathological states.
Source: HAL
Institutions: École Normale Supérieure Paris-Saclay, Biologie intégrée du globule rouge et de l'Erythropoïèse, Centre de Nanosciences et de Nanotechnologies, Université Gustave Eiffel, ESIEE Paris, Laboratoire d'électronique, systèmes de communication et microsystèmes, Laboratoire Lumière, Matière et Interfaces
Language: English
Subfield: Hematology
Field: Medicine
Domain: Health Sciences
Open Access status: green
Award: Saclay Plant Sciences
OpenAlex ID: W4286907171