Work

Burst-Mode Spontaneous Raman Thermometry.

Year: 2020
Type: article
Abstract: A high-speed Raman thermometry diagnostic was evaluated in lean H2air flames at a data acquisition rate of 5 kHz.Bursts of nanosecond pulses were generated at a 10 kHz burst rate with energy of E 7-' 13 J/burst at k = 532 nm.The pulses had duration of order 200 ns and were used to interrogate a stabilized flat flame burner.Spectra were collected using a spectrometer having focal length 0.32 meters and an electron multiplying charge-coupling device (EMCCD) detector.Raman spectra were integrated over the full burst to map adiabatic flame temperature versus equivalence ratio.The measured spectra resolved vibrational band features to infer temperature.A detailed spectral fitting model was used in the burst-integrated and burst-mode spectra.Two pulses were used for each burst-mode measurement resulting in a 5 kllz rate up to flame temperatures of about 2100 K.The measurement precision in burst mode was 23 K and 62 K at flame temperatures of 1160 K and 2080 K, respectively.The measurement accuracy was benchmarked against the spectrally fitted full-burst spectra, chemical equilibrium calculations and previous coherent anti-Stokes Raman (CARS) measurements.Finally, a path towards demonstration of this technique in a high-temperature shock tube is briefly outlined.I.
Language: English
Open Access status: green
OpenAlex ID: W4288007630
FWCI:
Cites: 22
Cited by:
Related to: 10