Dimensionnement et analyse d'un transformateur piézoélectrique dans une alimentation 30V/15V-5W pour une application spatiale
Year: 2008
Type: conference-paper
Abstract: Piezoelectric transformers (PT) are widely adopted in recent year due to many advantages, including safety, no EMI problem, low housing profile, and high power density, etc.The characteristics of the PT are well-known when the load impedance is a pure resistor.When PTs are used in AC/DC or DC/DC converters, there are always a rectifier circuit block connected after PT.The rectifier circuit block sometimes can be equivalent to a resistor, but not always true.Thus, this paper starts from the model of the voltage-mode rectifier directly.Then, three design constraints are discussed detail, including the minimum input voltage, maximum mechanical current and the constraint of the PT configuration.Different from the typical optimal loading condition of the PT, the concept of the maximum mechanical current leads a new optimal efficiency condition which is suitable for the voltage regulation.Further, the ability of the regulation and the efficiency are trade-off.This paper proposes a simple criterion to obtain the good regulation and good efficiency at the same time.Finally, the completed design procedure is discussed by a given specification.The PT derived from the proposed design procedure can guarantee both good efficiency and enough range of the voltage regulation.
Source: HAL
Authors: Liu, Yuan-Ping, Vasic, Dejan, Costa, François, Wu, Wen-Jong
Language: French
Topic: Advanced DC-DC Converters
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W4290091024