Abstract: Fermilab is currently building the Project X Injector experiment (PXIE).PXIE linac will accelerate 1 mA H - beam up to 30 MeV and serve as a testbed for validation of Project X concepts and mitigation of technical risks.A cryomodule of eight superconducting RF Single Spoke Resonators of type 1 (SSR1) cavities operating at 325 MHz is an integral part of PXIE.Ten SSR1 cavities were manufactured in industry and delivered to Fermilab.In this paper we discuss surface processing and tests of bare SSR1 cavities at the Fermilab Vertical Test Stand (VTS).We report on the measured performance parameters of nine cavities achieved during tests.