Work

Windcube Classification Sensitivity to Turbulence Intensity

Year: 2018
Type: conference-abstract
Abstract: Proper assessment of wind sensor sensitivities is paramount for correct evaluation of wind speed measurement uncertainties. This is why the classification test of at least two remote sensing devices units at a minimum of two locations is a requirement of the latest edition of IEC61400-12-1 (Annex L). In 2018, Deutsche WindGuard delivered the third classification test: Windcube is now fully compliant with all requirements of IEC61400-12-1. The classification test identified two influential environmental parameters: the turbulence intensity and the shear (to a lesser extent). The influence of turbulence intensity can be explained by the averaging method and confirmed with simulations. The development of this understanding along with data analysis of several Windcube dataset highlights a less sensitive reconstruction method called “vector averaging”. This method results in a lowering of the uncertainty for power curve and wind resource assessments.
Source: HAL
Language: English
Field: Energy
Open Access status: green
OpenAlex ID: W4298884699
Cites:
Cited by:
Related to: 10