Inadvertent placement of an esophagostomy tube into the mediastinum of a cat.

Year: 2022
Type: article
Study design: Case Report
Abstract: An 8-year-old neutered male Siberian forest cat was presented for respiratory distress. Endoscopy, exploratory surgery of the neck, and sternotomy confirmed initial placement of the esophagostomy tube (e-tube) into the mediastinum. The patient recovered from surgery, developed laryngeal paralysis, and then arrested and died within 48 h after surgery. Key clinical message: To the authors' knowledge, there are no other case reports documenting inadvertent placement of an e-tube into the mediastinum of a cat. This case report highlights the complications that can be associated with incorrect placement of an e-tube.
Authors: Shannon Kelly, Carsten Bandt
Language: English
Subfield: Small Animals
Field: Veterinary
Open Access status: green
OpenAlex ID: W4308182608
FWCI: 0.754
Cites: 13
Cited by: 3
Related to: 10