Experimental Study on the Discharge Coefficient for Side Weir with Pressurized Flow in Circular Channel
Year: 2013
Type: article
Abstract: Urban inundations are caused by natural climate change and torrential rainfall during a short-time. As wide permeable areas go through the process of urbanization, the most of the storm water dose not infiltrate into the ground and total amount of storm water runoff has increased. Likewise, insufficient drainage capacity and pump station, water retention system in metropolitan areas can also result in urban flooding. So, the researches for the mitigation the amount of storm water are essential. Due to this, underground storage systems are installed to mitigate damage of urban flooding. Estimation of overflowing discharge into those storage systems is significant for evaluation of their mitigation effects. Such overflow happens between pressurized sewer pipe and storage system over a side weir. The equation proposed by De Marchi to estimate overflow discharge over a side weir has been verified through several experimental researches only for open channel flow. Therefore in this study, overflow discharge coefficient is evaluated for pressurized flow of circular pipe through experiments with different side weir length. The discharge coefficient derived from experimental results implies applicability of constant value to estimate overflow discharge if mean value of integrated water head along the side weir is used, which should be verified through numerical simulation in the future.
Language: English
Subfield: Civil and Structural Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W431365375