Percutaneous closure of a cor triatriatum dexter with an inferior sinus venosus and secundum atrial septal defect without distance to coronary sinus ostium and a patent foramen ovale
Year: 2023
Type: article
Study design: Case Report
Abstract: A 49-year-old female with a history of cardiac murmur and migraine attributed to atrial septal defect (ASD) and patent foramen ovale (PFO) was admitted to our hospital for percutaneous closure of ASD and PFO confirmed by transoesophageal echocardiography (TEE). Pre-procedure TEE showed a cor triatriatum dexter with an inferior sinus venosus ASD (6 mm) (Figure 1A), a secundum ASD (15 mm) with no distance to coronary sinus ostium (CSO) (Figure 1B), and combined with a PFO (size 2.3 mm, tunnel length 8.8 mm) (Figure 1C). (A) Transoesophageal echocardiography showed a cor triatriatum dexter with an inferior sinus venosus atrial septal defect (6 mm). (B) Transoesophageal echocardiography showed a secundum atrial septal defect (15 mm) with no distance to coronary sinus ostium. (C) Transoesophageal echocardiography showed a patent foramen ovale (size 2.3 mm, tunnel length 8.8 mm). (D) Transoesophageal echocardiography indicated that the occluder was in good position with 2 mm residual shunt at inferior sinus venosus atrial septal defect and the coronary sinus ostium width was normal. (E) Coronary sinus ostium angiography showed that the coronary sinus ostium was compressed by about 30%, the blood flow was normal. The upper and lower parts of the right femoral vein were punctured under general anaesthesia. Under the guidance of TEE and fluoroscopy, a 0.035 inch 150 cm guidewire with assist of 6F MPA2 catheter was used to probe through the secundum ASD from the right atrium to the left atrium and then slip to left superior pulmonary vein. Exchange the delivery sheath with the stiffened guidewire. Considering no distance between the secundum defect and the CSO, a 20 mm ASD occluder (Scientech, China) was implanted. TEE indicated that the occluder was in good position with 2 mm residual shunt at inferior sinus venosus ASD and the CSO width was normal (Figure 1D). Then, the 20 mm ASD occluder was deployed successfully. After that, a 18/24 mm left-disc non-rivet PFO occluder (Scientech, China) was deployed successfully. CSO angiography showed that the CSO was compressed by about 30%; the blood flow was normal (Figure 1E). To our acknowledge, this is the first case of percutaneous interventional closure of a cor triatriatum dexter with a secundum ASD that has no distance to CSO and inferior sinus venosus ASD and PFO. We extend our gratitude to Prof. Xue-gang Xie from The First Affifiliated Hospital of Xi'an Jiaotong University for assistance with the procedure. Ethics Approval: This study was conducted in accordance with the Declaration of Helsinki. This study was conducted with approval from the Ethic committee of the First Affiliated Hospital of Xi’an Jiaotong University. Consent: Written informed consent to publish the clinical details and images of the patient was obtained. Funding: This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors. The datasets used and analysed during the current study are available from the corresponding author on reasonable request.
Language: English
Subfield: Pulmonary and Respiratory Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $707
OpenAlex ID: W4324356731