A mixed numerical-experimental approach to evaluate the internal soft tissue response of the heel
Year: 2022
Type: conference-paper
Abstract: Introduction: The heel is a common site for pressure ulcer development, particularly in people who are supine because of immobility. There is little protective subcutaneous tissue within the heel, making it vulnerable to pressure, friction and shear forces. The current clinical practice emphasizes the decrease of mechanical loads by providing support surfaces to relieve points of high interface pressure, however, treatment interventions based on this principle may not be effective. A biomechanical approach to evaluate the soft tissue injury risk is a potential solution towards a personalised estimate of this risk. In particular, the local mechanical environment within soft tissues has proved a valuable tool to assess soft tissue injury risk [Ceelen, 2008]. Two studies to date have assessed the influence of foot posture on the heel soft tissue strains. However, both these studies produced conflicting results, whereby high contact pressures and internal maximum shear strains at 90˚ dorsiflexion were reported for a Korean male [Zwam, 2020] compared to an abducted foot orientation of 60˚ for an American male [Sopher 2011]. Both these studies generated an FE model of the left foot from cadaveric data; however, the demographics of each cadaver may have influenced their findings. The objective of this study was therefore twofold; (a) to propose a mixed numerical-experimental approach to evaluate the internal soft tissue response of the heel in clinically relevant positions and (b) to evaluate the impact of assumed literature values for constitutive parameters.Methods: A T2-MRI scan of the foot was captured in both an unloaded and loaded configuration for one female volunteer (aged 33, 1.70m and 52kg) in supine. The same participant then underwent an EOS and US scan simultaneously in 6 configurations: unloaded, loaded, 60˚ abduction, 60˚ adduction, 90˚ dorsiflexion and 30˚ plantarflexion (Figure 1). Pressure measurements were also acquired using a Zebris FDM pressure platform. The data was then postprocessed to develop a 3D MRI-based FE model, where both Neo-hookean and Ogden constitutive parameters were assumed. The MRI data was then segmented and imported into the EOS biplanar radiographs such that each bone could be repositioned according to the bone contours in the radiograph. The loading conditions were then simulated by applying a gravity load to the FE model in the reference undeformed configuration. The vertical displacement of the bone, the local log strain and the contact pressure were extracted for analysis. The simulated FE results were then compared to the acquired experimental data.Results and Discussion: The FE simulations showed high internal strains (above 0.2) in the heel soft tissue. This was consistent with the US-derived strains. The strain localisation changed with the various test configurations, highlighting the importance of accounting for patient-specific geometry and repositioning. Results obtained using Ogden constitutive parameters were different from those obtained assuming Neo-hookean - indicating the need for subject-specific calibration. This is the first step for evaluating the predictive performance of our FE model. Perspective work will focus on different subgroups in order to assess inter-subject variability and the effect this has on material properties.
Source: HAL
Authors: Keenan, Bethany, E, Rohan, Pierre-Yves
Language: French
Subfield: Dermatology
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W4378092932