Year: 1987
Type: article
Abstract: (J. Extra-Corpor. Technol. 19[4]: p. 408-411 Winter 1987). Programmable calculators have become increasingly valuable to the conduct of cardiopulmonary bypass (CPB). We report the upgrading of our previous system with current technology. A Sharp PC-2500 portable microcomputer was chosen because of its low cost, easy programmability, rechargeable battery, and built-in printer. This system has allowed perfusionists to perform an increasing number of complex calculations with more accuracy and efficiency. In addition, it offers expanded memory and a permanent record of its calculations. We have used the new system in over 250 cases of CPB without problem. Although the flexibility of such a system allows customization to fit individual needs, we advise that any program be carefully tested and debugged to prevent serious mishap.
Institution: Columbia University
Language: English
Subfield: Surgery
Field: Medicine
Domain: Health Sciences
Open Access status: bronze
Funder: U.S. Public Health Service
OpenAlex ID: W4386238610