The Effectiveness of a Mechanical Ventilation System for Indoor PM2.5 in Residential Houses
Year: 2023
Type: article
Abstract: Mechanical ventilation systems used in houses are designed to reduce carbon dioxide emissions while minimizing the energy loss resulting from ventilation. However, increase in indoor fine particulate (PM2.5) concentration because of external PM2.5, influx through the ventilation system poses a problem. In this study, we analyzed the changes in indoor PM2.5 concentrations via dis-tinguishing between cases of high and low outdoor PM2.5 concentrations, considering the effi-ciency of filters used in residential mechanical ventilation systems. When using minimum effi-ciency reporting value (MERV) 10 filters in the ventilation system, the outdoor PM2.5 concentra-tion was 5 μg/m³; the indoor PM2.5 concentration became 73% after 60 min compared to the ini-tial. When the outdoor PM2.5 concentration was 30–40 μg/m³, the indoor PM2.5 concentration reached 91%. However, when MERV 13 filters were used, the indoor PM2.5 concentration con-sistently dropped to 73–76% regardless of the outdoor PM2.5 concentration. Furthermore, by comparing the established equation with the mass-balance model, the error was confirmed to be within 5%, indicating good fit. This allows the prediction of indoor PM2.5 under various condi-tions when using mechanical ventilation systems, enabling the formulation of strategies to maintain indoor PM2.5 as recommended by the World Health Organization.
Source: Toxics
Institutions: Korea Institute of Machinery & Materials, Yonsei University
Language: English
Subfield: Health, Toxicology and Mutagenesis
Field: Environmental Science
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $2,224
Awards: G5464763396, G8712094000
OpenAlex ID: W4388451626