Bridging the gap: improving correspondence between low-field and high-field magnetic resonance images in young people
Year: 2024
Type: article
Abstract: Background Portable low-field-strength magnetic resonance imaging (MRI) systems represent a promising alternative to traditional high-field-strength systems with the potential to make MR technology available at scale in low-resource settings. However, lower image quality and resolution may limit the research and clinical potential of these devices. We tested two super-resolution methods to enhance image quality in a low-field MR system and compared their correspondence with images acquired from a high-field system in a sample of young people. Methods T1- and T2-weighted structural MR images were obtained from a low-field (64mT) Hyperfine and high-field (3T) Siemens system in N = 70 individuals (mean age=20.39 years, range 9-26 years). We tested two super-resolution approaches to improve image correspondence between images acquired at high- and low-field: 1) processing via a convolutional neural network (‘SynthSR’), and 2) multi-orientation image averaging. We extracted brain region volumes, cortical thickness, and cortical surface area estimates. We used Pearson correlations to test the correspondence between these measures, and Steiger Z tests to compare the difference in correspondence between standard imaging and super-resolution approaches. Results Single pairs of T1- and T2-weighted images acquired at low field showed high correspondence to high-field-strength images for estimates of total intracranial volume, surface area cortical volume, subcortical volume, and total brain volume ( r range=0.60-0.88). Correspondence was lower for cerebral white matter volume ( r= 0.32, p= .007, q= .009) and non-significant for mean cortical thickness ( r= -0.05, p= .664, q = .664). Processing images with SynthSR yielded significant improvements in correspondence for total brain volume, white matter volume, total surface area, subcortical volume, cortical volume, and total intracranial volume ( r range=0.85-0.97), with the exception of global mean cortical thickness ( r =0.14). An alternative multi-orientation image averaging approach improved correspondence for cerebral white matter and total brain volume. Processing with SynthSR also significantly improved correspondence across widespread regions for estimates of cortical volume, surface area and subcortical volume, as well as within isolated prefrontal and temporal regions for estimates of cortical thickness. Conclusions Applying super-resolution approaches to low-field imaging improves regional brain volume and surface area accuracy in young people. Finer-scale brain measurements, such as cortical thickness, remain challenging with the limited resolution of low-field systems.
Source: Frontiers in Neurology
Authors: Rebecca Cooper, Rebecca Hayes, Mary Corcoran, Kevin N Sheth, Thomas Campbell Arnold, Joel Stein, David C. Glahn, Maria Jalbrzikowski
Language: English
Subfield: Radiology, Nuclear Medicine and Imaging
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $3,295
Funders: Howard Hughes Medical Institute, National Institutes of Health, National Institute of Mental Health, National Institute of Neurological Disorders and Stroke, National Institute of Biomedical Imaging and Bioengineering, Eunice Kennedy Shriver National Institute of Child Health and Human Development
Awards: Ghost in the Machine: Melding Brain, Computer and Behavior, G6688787955, Acquisition of a Siemens 3T MRI for Research Imaging, Boston Children's Hospital/HMS Intellectual and Developmental Disabilities Research Center, Predicting psychosis risk in youth using a novel structural neuroimaging score that measures deviation from normative development. Can we bring it to communities using portable, low-field MRI?, TRAINING PROGRAM IN BIOMEDICAL IMAGING AND INFORMATIONAL SCIENCES
OpenAlex ID: W4393099162