Work

The i‐gel® supraglottic airway device compared to endotracheal intubation as the initial prehospital advanced airway device: A natural experiment during the COVID‐19 pandemic

Year: 2024
Type: article
Study design: Observational Study
Abstract: Objective Unlike randomized controlled trials, practical real-world studies can offer important information about implementation of prehospital interventions, particularly in community settings where there may be reluctance to adopt new practices. We present the results of a natural experiment that was driven by mandated COVID-19 pandemic-driven shift from endotracheal intubation (ETI) to the i-gel® supraglottic airway (SGA) as a primary advanced airway management device in the prehospital setting to reduce emergency medical services (EMS) personnel exposure to potentially infectious secretions. The objective was to compare first-pass success and timing to successful airway placement between ETI and the i-gel® SGA under extenuating circumstances. Methods This pre/post study compared airway placement metrics in prehospital patients requiring advance airway management for non-trauma-related conditions. Data from EMS records were extracted over 2 years, 12 months pre-pandemic, and 12 months post-pandemic. During the pre-COVID-19 year, the EMS protocols utilized ETI as the primary advanced airway device (ETI group). Post-pandemic paramedics were mandated to utilize i-gel® SGA as the primary advanced airway device to reduce exposure to secretions (SGA group). Results There were 199 adult patients, 83 (42%) in the ETI group and 116 (58%) in the SGA group. First-pass success was significantly higher with SGA 96% (92%–99%) than ETI 68% (57%–78%) with paramedics citing the inability to visualize the airway in 52% of ETI cases. Time to first-pass success was significantly shorter in the SGA group (5.9 min [5.1–6.7 min]) than in the ETI group (8.3 min [6.9–9.6 min]), as was time to overall successful placement at 6.0 min (5.1–6.8 min) versus 9.6 min (8.2–11.1 min), respectively. Multiple placement attempts were required in 26% of ETI cases and 1% of the SGA cases. There were no statistically significant differences in the number and types of complications between the cohorts. Return of spontaneous circulation (on/before emergency department [ED] arrival), mortality at 28 days, intensive care unit length of stay, or ventilator-free days between the groups were not statistically different between the groups. Conclusion In this natural experiment, the SGA performed significantly better than ETI in first-pass airway device placement success and was significantly faster in achieving first-pass success, and overall airway placement, thus potentially reducing exposure to respiratory pathogens. Practical real-world studies can offer important information about implementation of prehospital interventions, particularly in community settings and in systems with a low frequency of tracheal intubations.
Language: English
Field: Medicine
Open Access status: gold
Estimated APC paid: $2,200
OpenAlex ID: W4393947479
FWCI: 0.548
Cites: 27
Cited by: 2
Related to: 10