Work

Delayed orbital floor implant complications: Case report and review of the literature

Year: 2024
Type: article
Study design: Case Report
Abstract: Purpose: Foreign body reaction to non-absorbable alloplastic orbital implants utilized for bony reconstruction are infrequently documented in the literature. We present the workup and surgical management of a giant cystic mass encapsulating a patient's alloplastic orbital implant, which was ultimately deemed to be a result of foreign body reaction. Observations: A 41-year-old male patient with distant history of a right orbital floor fracture had undergone repair with the placement of a nylon foil implant. The patient presented twenty years later with progressive ipsilateral globe proptosis and was found to have a giant inferior orbital cyst. Surgical exploration and removal of the implant and capsule were performed. Histopathology confirmed a delayed foreign body reaction around the patient's alloplastic implant. Conclusions: Alloplastic implants may result foreign body reaction and cyst encapsulation as a delayed complication.
Language: English
Subfield: Surgery
Field: Medicine
Open Access status: gold
Estimated APC paid: $1,340
OpenAlex ID: W4394865294
FWCI:
Cites: 19
Cited by:
Related to: 10