Aortic Valve Replacement
Year: 2024
Type: article
Study design: Case Report
Abstract: Implantation of prosthetic heart valves may result in both early and late complications. Early complications are usually structural and can have significant hemodynamic consequences. In this clinical vignette, we highlight how malposition of a newly implanted aortic valve resulted in alterations of coronary perfusion pressure physiology and subsequent significant hemodynamic effects.
Source: JACC Case Reports
Authors: Faraz Mahmood, Aidan Sharkey, Feroze Mahmood, Raghav Seth, David Liu, Roger Laham
Language: English
Subfield: Cardiology and Cardiovascular Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $850