Work

Optimization of glass spray tempering parameters based on response surface methodology and economic analysis

Year: 2024
Type: article
Abstract: Glass curtain walls have gained significant popularity as building enclosure structures, owing to their exceptional performance. Consequently, it becomes imperative to reduce energy consumption during the glass tempering process to ensure sustainable development within the construction industry. In this study, an experimental design was conducted using the response surface methodology (RSM). The particle count and cooling energy consumption were selected as the response value, while the influencing factors included four process parameters, namely, the spray distance ( H ), mist load fraction ( f ), spray pressure ( p ), and final cooling temperature ( T z ). The second order model fitting of the RSM was used to obtain the polynomial regression equation between each response and each factor. Under the optimized conditions of H = 200 mm, f = 1.03, p = 0.5 MPa, and T z = 150 °C, the number of fractured glass particles was found to be 234, and the cooling energy consumption was 0.00048 kW·h. Further analysis indicated that under these spray conditions, the net present value was 523.90 k$, and the dynamic payback period was 1.1 years. Compared to traditional air-cooled tempering, spray tempering demonstrated superior economic performance.
Authors: Tian Liang, Wang Liangliang, Zhao Fuxing, Liu Fengxiao
Language: English
Open Access status: hybrid
Estimated APC paid: $3,790
OpenAlex ID: W4402177624
FWCI: 0.672
Cites: 35
Cited by: 5
Related to: 10