Abstract: We report pulsed laser emission using fluorescein combined with avidin as an active medium matrix in a Littrow cavity configuration. The study covers testing several solvents and a range of excitation energies, aiming to get the narrowest bandwidth for stable peak emission wavelength. Initially, for 4 mM of fluorescein in 1:1 mixture of methanol:NSS, and excited with 20.80 mJ of energy, a laser mission of 4.38 nm bandwidth is achieved. Then, different concentrations of thiolated avidin are mixed in the active medium, causing related red-shifts over the initial emission band. Substantial spectral changes are observed down to 0.3 μM of avidin, making apparent the stability conditions for this sort of laser system to work out as a biosensor.