Radon exhalation rate from the latex pillows and its potential exposure to users
Year: 2024
Type: article
Abstract: Objective To develop a new system to accurately measure the radon exhalation from the latex pillows, and to estimate its potential exposure to users. Methods The new system is composed of two loops, the first loop is designed to trap background radon and thoron until their levels are nearly zero, and the second loop is the measurement loop to detect radon and thoron exhalation rates from the pillows. Results The results showed that mass radon exhalation rated ranged from 0.18 Bq·kg −1 ⋅h −1 to 0.78 Bq·kg −1 ⋅h −1 , with an average of (0.36 ± 0.17) Bq·kg −1 ⋅h −1 in the 9 samples. The average annual effective dose to users in a model room was estimated to be (15.51 ± 12.69) μSv by assuming two pillows was used. Conclusion These results demonstrate that the new system can effectively measure radon exhalation rates in latex pillows, and the potential exposure to radon exhalating from the pillows is very low.
Language: English
Subfield: Radiological and Ultrasound Technology
Field: Health Professions
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $2,000
OpenAlex ID: W4402666258