A green and sensitive electromembrane extraction (EME) method for the determination of dialkylphosphates in maternal urine and amniotic fluid
Year: 2024
Type: article
Abstract: • Electro-assisted liquid phase microextraction reveals high sensitivity for DAPs analysis. • DAPs were quantified in maternal urine and amniotic fluid samples. • DMTP, DEP and DBP emerged as the predominant DAP in both sample types. Organophosphates compounds are extensively used pesticides, whose metabolites, dialkyl phosphates, are considered as bioindicators of human exposure. Recently, research has indicated that they can affect thyroid endocrine function. Pregnant women are a particularly vulnerable cohort to these effects due to concerns about prenatal exposure to environmental pollutants. For the first time an electromembrane microextraction method is proposed for the simultaneous determination of seven dialkylphosphate metabolites in maternal urine and amniotic fluid, which is compatible with mass spectrometry detection and achieves highly sensitive levels of quantitation. Dialkylphosphates were extracted from a 10 mL donor solution at pH 7 into a 50 µL acceptor solution at pH 12 using 1-octanol as the supported liquid membrane and applying 60 V for 10 min at 600 rpm. The obtained extracts were analysed by ion pair liquid chromatography coupled to a triple quadrupole mass spectrometer, using an Acquity UPLC® BEH C18 column (100 mm × 2.1 mm i.d., 1.7 µm particle size) at 30 °C. Under optimal extraction conditions, the preconcentration factors were achieved were up to 178-fold, allowing for high sensitivity levels, in the order of ng mL −1 . The limits of quantitation were within 0.075 ng mL −1 (diethyl thiophosphate) and 1.67 ng mL −1 (dimethyl phosphate) in maternal urine samples and within 0.015 ng mL −1 (diethyl thiophosphate) and 0.5 ng mL −1 (dimethyl dithiophosphate) in amniotic fluid samples. The comparative study revealed a significant improvement in terms of analysis time, sensitivity, greenness, and practicality. Finally, the applicability of the method for the determination of selected dialkylphosphates was demonstrated in paired maternal urine and amniotic fluid samples. These results suggest potential placental transfer to the offspring.
Source: Microchemical Journal
Institution: Universidad de Sevilla
Language: English
Subfield: Analytical Chemistry
Field: Chemistry
Domain: Physical Sciences
Open Access status: hybrid
Estimated APC paid: $3,720
Awards: G5710606591, G6368336893, G8698115087
OpenAlex ID: W4402700964
