Sizing Behind-the-Meter Solar PV Systems for Water Distribution Networks
Year: 2024
Type: conference-paper
Abstract: This study investigates three methods for sizing behind-the-meter (BTM) solar PV systems for pumped water distribution networks (WDNs). The three methods are (1) the industry method based on current industry practices, (2) the minimum total life cycle cost (TLCC) method to minimize TLCC through the life of solar PV systems, and (3) the minimum payback method to minimize the time to pay off the capital investment in solar PV systems. The industry method risks over-sizing, while the minimum payback method risks under-sizing. The minimum TLCC method leads to systems with balanced performance. The findings offer decision-makers insights when selecting solar PV systems for WDNs.
Institutions: The University of Melbourne, The University of Adelaide
Language: English
Subfield: Civil and Structural Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: gold
OpenAlex ID: W4402748103