Comparison between digital vaginal examination and ultrasound parameters to assess fetal head station and position in labour

Year: 2024
Type: article
Study design: Observational Study
Abstract: Background: The aim was to study the comparison between digital vaginal examination and ultrasound parameters to assess fetal head station and position in labour. The objective was to determine the level of agreement and to compare the findings of clinical examination with intrapartum ultrasound in the determination of fetal head station and position in labour. Methods: A prospective cohort study was done over a period of 12 months in a tertiary centre. 86 patients were followed up by digital vaginal examination and intrapartum ultrasound for determining the fetal head position and station in active labour. Categorical variables were presented in number and percentage, and continuous variables presented as mean±SD and median. Qualitative variables were correlated using Chi-square test. A p value of <0.05 was considered statistically significant. Results: The absolute agreement between DVE and intrapartum USG for determining FHP was 43.02% in labour with a composite agreement of 66.67%. The absolute agreement between DVE and Intrapartum USG for determining fetal head station was 68.6% in labour. Accuracy of ultrasound to correctly diagnose fetal head position in labour was found to be 82.14%. Conclusions: DVE is a subjective tool which can fail to detect the correct fetal head position and station in labour in presence of certain conditions like caput succedaneum and moulding during active labour.
Language: English
Field: Medicine
Open Access status: diamond
OpenAlex ID: W4402879057
FWCI: 0.482
Cites:
Cited by: 1
Related to: 10