Work

Physiologically-based pharmacokinetic modelling in sepsis: A tool to elucidate how pathophysiology affects meropenem pharmacokinetics

Year: 2024
Type: article
Abstract: • A physiologically-based pharmacokinetic model adapted to the pathophysiology in sepsis was able to describe the plasma and subcutaneous tissue exposure of meropenem in septic patients. • Changes in meropenem distribution may be linked to expected changes in body composition (especially interstitial space volume) in sepsis patients. • The model could be further expanded to provide a generic physiological modelling framework in septic patients by applying it to other entities with different physicochemical and PK properties. Applying physiologically-based pharmacokinetic (PBPK) modelling in sepsis could help to better understand how PK changes are influenced by drug- and patient-related factors. We aimed to elucidate the influence of sepsis pathophysiology on the PK of meropenem by applying PBPK modelling. A whole-body meropenem PBPK model was developed and evaluated in healthy individuals, and renally impaired non-septic patients. Sepsis-induced physiological changes in body composition, organ blood flow, kidney function, albumin, and haematocrit were implemented according to a previously proposed PBPK sepsis model. Model performance was evaluated, and a local sensitivity analysis was conducted. The model-predicted PK metrics (AUC, C max , CL, V ss ) were within 1.33-fold-error margin of published data for 87.5% of the simulated profiles in healthy individuals. In sepsis, the model provided good predictions for literature-digitised average plasma and tissue exposure data, where the model-predicted AUC was within 1.33-fold-error margin for 9 out 11 simulated study profiles. Furthermore, the model was applied to individual plasma concentration data from 52 septic patients, where the model-predicted AUC, C max , and CL had a fold-error ratio range of 0.98–1.12, with alignment of the predicted and observed variability. For V ss , the fold-error ratio was 0.81, and the model underpredicted the population variability. CL was sensitive to renal plasma clearance, and kidney volume, whereas V ss was sensitive to the unbound fraction, organ volume fraction of the interstitial compartment, and the organ volume. These findings may be extended to more diverse drug types and support a more mechanistic understanding of the effect of sepsis on drug exposure.
Language: English
Subfield: Pharmacology
Field: Medicine
Open Access status: hybrid
Estimated APC paid: $3,280
OpenAlex ID: W4402910090
FWCI: 1.672
Cites: 44
Cited by: 7
Related to: 10