Application of multispectral optoacoustic tomography for lower limb musculoskeletal sports injuries in adults
Year: 2024
Type: article
Study design: Observational Study
Abstract: Compositional changes in relation to musculoskeletal injuries are difficult to measure non-invasively. This study aims to use non-invasive label-free imaging with Multispectral Optoacoustic Tomography (MSOT) to evaluate compositional changes with injury. Five different patient groups were examined, covering diagnoses of Achilles or patellar tendinopathy, Achilles tendon rupture and gastrocnemius muscle strain injury. Injured and contralateral limbs were imaged using a commercial MSOT device. Hemoglobin, collagen, and lipid contents were estimated. Some patients were examined before and after exercise. Hemoglobin measures had high reproducibility and displayed systematic changes in response to exercise. The content and exercise response of hemoglobin was equal on both limbs. In contrast, collagen and lipid measures were inconsistent and did not display the expected distribution. In conclusion, MSOT is applicable to imaging of hemoglobin in musculoskeletal injuries, providing complimentary information to conventional ultrasound, but applicability to other components like collagen and lipids could not be shown.
Source: Photoacoustics
Language: English
Subfield: Biomedical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $2,810
Awards: G1569471583, G2353501137