Research on Denoising Algorithm of Standpipe Pressure Signal in FCC Device Based on Tortuosity and Denoising Intensity
Year: 2024
Type: article
Abstract: The pressure signal of the standpipe in the regeneration device for the catalytic cracking reaction is commonly used as a basis for equipment fault diagnosis. The device operates in environments of high temperature, strong vibration, and high flow rate. The standpipe pressure signal is easily interfered with by noise, making it difficult to extract pressure characteristics. In this study, a signal denoising algorithm based on pressure curve tortuosity and denoising intensity is proposed. A power spectrum threshold vector is utilized to filter the pressure in the circulating standpipe, and the denoising intensity and tortuosity after denoising are calculated. Taking the ratio of noise reduction intensity and tortuosity as the objective function, the noise reduction scheme of the pressure signal at different heights of the standpipe is determined. The denoised pressure signals are reconstructed, and the characteristic pressure signals of the circulating standpipe are extracted. The results indicate that the method suppressed the noise, enhanced the significance of characteristic parameters, and improved the accuracy of the fault diagnosis in the FCC units.
Source: ACS Omega
Language: English
Subfield: Control and Systems Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $1,935
Awards: G1560785894, G8514328800
OpenAlex ID: W4403286798