Piezoelectric barium titanate/hydroxyapatite composite coatings on Ti-6Al-4V alloy via electrophoretic deposition
Year: 2024
Type: article
Abstract: ) of 159 pC/N and Vicker's hardness of 242.31 HV. The cross-sectional electron micrographs show well connected and homogeneous coatings with increasing amounts of BT. Human mesenchymal stem cell lines were utilized in biocompatibility experiments, which revealed that HB composites had greater viability of HW-MSCs cells than pure BT, with HB6 exhibiting a maximum cell viability of more than 90 %.
Source: Heliyon
Authors: Akhila S Nair, Leema Rose Viannie
Institution: Vellore Institute of Technology University
Language: English
Subfield: Biomedical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $2,100