Work

Air to liquid heat transfer coefficient experimental comparison between silicon carbide and glass shell and tube heat exchangers in a pilot plant scale

Year: 2024
Type: article
Abstract: Instead of the expected 3.8–5.4% increase in the heat transfer coefficient due to the better thermal conductivity of silicon carbide tubes compared to glass tubes, the observed increase was 18–22% for 150–275 kg·h−1 airflow and 6 kg·s−1 propane-1,2-diol coolant in tubes. This additional 15–17% increase is probably due to local flow turbulisation due to the roughness of the sintered carbide of 4–10 µm, which unfortunately also causes a 17–24% higher air pressure drop. The hand calculation model used underestimates the heat transfer coefficient by −2% to 10%, which is better than CHEMCAD 8 modeling results.
Language: English
Open Access status: hybrid
OpenAlex ID: W4403372168
FWCI:
Cites: 4
Cited by:
Related to: 10