An update on soil gas harvesting technique as a non-depleting source of 222Rn for a large volume calibration chamber for long-term exposure experiments

Year: 2024
Type: article
Abstract: To demonstrate the versatility of the natural soil gas harvesting technique, coupled with a semi-dynamic injection algorithm, as an efficient and reliable source for continuous 222 Rn delivery to a large-volume calibration chamber across different soil conditions and climatic conditions. Long-term experiments were performed during three seasons of a year in a tropical monsoonal climatic region with high rainfall on the Southwest Coast of India. Soil gas extraction was performed using soil-gas probes, inserted to 1 ​m deep into the ground. Soil gas was harvested at a flow rate of 60 L/min, passed through a moisture trap, a 222 Rn progeny filter, and a delay volume and pumped into a 222 Rn calibration chamber of volume 22.7 ​m 3 . Continuous monitoring of 222 Rn concentration in the chamber was performed using ionization chamber-based reference monitors. To achieve and maintain the desired 222 Rn concentration values in the calibration chamber, the semi-dynamic injection method was adopted, in which the 222 Rn concentration in the soil gas was monitored periodically, and injection into the chamber was controlled using a well-defined pumping algorithm. Three ranges of 222 Rn concentration values were chosen as the target values to be maintained in the calibration chamber for long-term experiments (15 ​d): low concentration (500–1,000 Bq/m 3 ), medium concentration (1,000–10,000 Bq/m 3 ), and high concentration (10,000–25,000 Bq/m 3 ). The achieved 222 Rn concentration values were in good agreement with the target values, with deviations of 12%, 8% and 5% for the low, medium and high concentration exposures, respectively, during the summer season. During the monsoon season, the deviations between the target and the achieved concentration values were 12%, 10% and 5% for low, medium and high concentration exposures, respectively, and the corresponding deviations were 12%, 4%, and 5% for the winter season. These deviations are well within the cumulative uncertainty associated with the measurements. The results of this study conclusively demonstrate that the soil gas harvesting method, when coupled with the semi-dynamic injection approach, is a reliable method for generating and maintaining the desired 222 Rn concentration in the large volume calibration chamber during different seasons and environmental conditions. • This an update on soil gas harvesting technique as a non-depleting source of 222 Rn. • Long-term (up to 15 ​d) experiments were conducted in three seasons of a year. • Applicability of the 222 Rn gas harvesting from soil is demonstrated for different soil conditions. • Wide ranges of 222 Rn values (500–25000 ​Bq/m 3 ) were achieved in large volume calibration chamber. • Laboratories may increasingly utilize this technique for research as teaching programmes.
Authors: A.P. Vijith, N. Karunakara
Language: English
Open Access status: gold
Estimated APC paid: $2,000
OpenAlex ID: W4403464606
FWCI: 0.803
Cites: 14
Cited by: 2
Related to: 10