Pacemaker lead extraction saved a severe lead-induced tricuspid regurgitation: a case report
Year: 2024
Type: article
Study design: Case Report
Abstract: Background: Pacemaker lead-induced tricuspid regurgitation is a common complication after cardiac implantable electronic device (CIED) implantation. Cardiac implantable electronic device lead removal is a challenge procedure. Case summary: A 72-year-old lady was admitted due to worsening heart failure. She had a history of permanent atrial fibrillation and had a permanent single-chamber pacemaker implanted 8 years ago due to complete heart block. Transthoracic echocardiography identified severe lead-related tricuspid regurgitation. The patient underwent successful lead extraction and received a new implantation of left bunch bundle area pacing. Transthoracic echocardiographic examination 2 days after the procedure showed a significant decrease of the tricuspid regurgitation. The patient also reported an improvement in heart failure symptoms. Discussion: Pacemaker lead-related tricuspid regurgitation introduces negative haemodynamic overload, carrying high risk for the development of heart failure and worse outcome. The present case shows a rapid relief of symptom and improvement of echocardiography findings, indicating the significance of mechanistic approach in the treatment of lead-related tricuspid mechanical interference.
Language: English
Subfield: Cardiology and Cardiovascular Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $819
OpenAlex ID: W4403524162