Work

Robot-assisted percutaneous scaphoid fixation: patient-reported outcomes and learning curve at two centres

Year: 2024
Type: article
Abstract: This study describes patient-reported outcomes of robot-assisted percutaneous scaphoid fracture fixation of 62 patients from two medical centres and the learning curve of this new technique. One attempt to place the guidewire was sufficient in 97% of cases. All fractures achieved radiographic union at a mean of 9 weeks. There were no complications observed. At a mean follow-up of 36 months (range 12–68 months), the mean patient-rated wrist evaluation (PRWE) was 2 (range 0–22) and the mean Mayo Wrist Score was 96 (range 70–100). After the initial ten to 20 cases, the learning phase was reasonably surmountable with a marked reduction of operative duration and improvement of the screw accuracy. Level of evidence: IV
Language: English
Subfield: Surgery
Field: Medicine
Open Access status: bronze
OpenAlex ID: W4403843559
FWCI: 2.285
Cites: 26
Cited by: 6
Related to: 10