Work

Analysis of Shielding Performance in Double-Layered Enclosures with Integrated Absorbers

Year: 2024
Type: article
Abstract: Generally, various technologies, including waveguide below cutoff (WBC), gasket sealing, and bonding, are employed in metallic enclosures to achieve the high electromagnetic shielding performance required for EMP protection and EMC countermeasures in shielding structures or facilities. While the shielding structure or facility is properly constructed and maintained according to design specifications, its electromagnetic shielding performance can remain at the required level, effectively protecting internal electrical and electronic equipment from external electromagnetic interference. However, unintended apertures often occur during the construction or maintenance of shielding facilities, compromising their shielding performance. Therefore, it is crucial to develop technologies that prevent shielding effectiveness degradation caused by both intentional and unintentional apertures. This paper proposes a structure incorporating a composite absorber (made of dielectric and magnetic absorber) within a double metal panel of enclosure featuring an aperture, aimed at maintaining and improving the facility’s shielding performance. The effectiveness of the proposed structure was validated through numerical simulation.
Source: Electronics
Language: English
Open Access status: gold
Estimated APC paid: $2,728
OpenAlex ID: W4404113446
FWCI: 0.463
Cites: 16
Cited by: 6
Related to: 10