Determination of metal crack resistance on half-size Charpy specimens at cryogenic temperatures
Year: 2024
Type: article
Abstract: The work consists in the manufacture of experimental equipment for fracture toughness tests at cryogenic temperatures in the range from -196 °Cto -80 °Cand the analysis of the efficiency of determining the reference temperature of a metal by the maker curve for static crack resistance in accordance with ASTM E 1921 and ASTM E399. Liquid nitrogen and its vapours were used to cool the samples to the required temperature. The temperature stability during sample loading was ensured within ±0.5°C around the required temperature. Pre-cracking of the samples was carried out at room temperature in accordance with ASTM E647. Experimental studies on static crack resistance are carried out for three-point bending using half-size Charpy specimens (55×10×5 mm) for the material - 10GN2MFA steel, which is used as the main metal for the main circulation pipelines of VVER-1000. The reference temperature is determined by processing a set of relevant experimental data.
Language: English
Subfield: Mechanics of Materials
Field: Engineering
Domain: Physical Sciences
Open Access status: diamond
OpenAlex ID: W4404113606