Work

Recurrence Detection by Hybrid [ 18F ] FDG ‐ PET in Advanced Head and Neck Squamous Cell Carcinoma

Year: 2024
Type: article
Study design: Observational Study
Abstract: BACKGROUND: F]FDG-PET imaging is well established. However, there is ongoing debate regarding the optimal frequency of hybrid PET scans to be included in follow-up protocols, particularly if the initial post-therapeutic scan is negative. METHODS: We conducted a single-center 10-year retrospective study involving all patients who underwent hybrid PET scans for the follow-up of advanced stage head and neck cancer. A total of 285 patients were included. RESULTS: Out of 199 patients with a negative 3-month hybrid PET, 15% subsequently developed a recurrence during further follow-up. Notably, 90% of these recurrences were detected by hybrid PET. CONCLUSION: Fifteen percent of patients with a negative 3-month hybrid PET experienced a recurrence. Given that the majority of recurrences were detected by hybrid PET scans, there is a compelling argument for incorporating regular repetitive scans during follow-up.
Source: Head & Neck
Language: English
Field: Medicine
Open Access status: hybrid
Estimated APC paid: $4,760
OpenAlex ID: W4404197725
FWCI: 0.382
Cites: 32
Cited by: 1
Related to: 10