Work

Study on Windage Response Suppression of Large-Span Transmission Tower-Line System Using a Spring-Pendulum Dynamic Vibration Absorber

Year: 2024
Type: article
Abstract: Insulators and conductors in transmission line systems are susceptible to wind-induced movements, especially when insulators are closely positioned to transmission towers, potentially leading to electrical discharge. To address this issue, this study proposes a spring-pendulum dynamic vibration absorber (SPDVA) for windage suppression in transmission line systems. Using a finite element model based on an actual transmission line project, the study investigates SPDVA’s effectiveness in mitigating windage responses under varying wind speeds. The analysis considers mass and stiffness parameters to elucidate SPDVA’s suppression mechanism. The results indicate that SPDVA outperforms the additional heavy hammer method in suppressing insulator windage responses and also affects the peak acceleration response at the insulator’s bottom. Increasing stiffness initially enhances SPDVA’s suppression effectiveness on both peak and mean square deviation windage angle responses, peaking at 10 kN/m stiffness, while increasing the mass of the mass block also enhances suppression effectiveness.
Source: Energies
Language: English
Open Access status: gold
Estimated APC paid: $2,955
OpenAlex ID: W4404240444
FWCI: 0.675
Cites: 20
Cited by: 4