Work

Case Report: Zero-contrast balloon pulmonary angioplasty guided by real-time fusion of CT angiography with x-ray fluoroscopy

Year: 2024
Type: article
Study design: Case Report
Abstract: Background: Allergy to iodine contrast agents has long been a contraindication for balloon pulmonary angioplasty (BPA). We report the successful zero-contrast BPA procedure of a patient with inoperable chronic thromboembolic pulmonary hypertension (CTEPH) and severe iodine allergy using real-time fusion of computed tomography angiography (CTA) with x-ray fluoroscopy. Case presentation: A 62-year-old woman with CTEPH who developed a severe allergic reaction after the first BPA procedure. The second BPA procedure was successfully performed using the fusion of previous pulmonary artery CTA images and real-time fluoroscopy images. Pulmonary artery pressure showed a significant decrease after performing BPA twice. As of 6-month follow-up, the patient has recovered well. Conclusion: 3 Dimensions (3D) reconstruction of CTA images and real-time fluoroscopic image fusion navigation technology provide a new option for BPA treatment in patients allergic to iodine contrast agents.
Language: English
Field: Medicine
Open Access status: gold
Estimated APC paid: $3,295
OpenAlex ID: W4404494821
FWCI:
Cites: 12
Cited by:
Related to: 10