Field Measurement on Skin Temperature and Thermal Comfort of the Human Body with Various Wind Directions
Year: 2024
Type: conference-paper
Abstract: The desk fan as a personal thermal comfort (PTC) device remains an effective thermal adaptation method for office building applications, offering indoor thermal comfort to occupants.However, there are research gaps related to its effect on the skin temperature of office occupants.This study addresses these research gaps by conducting field measurements inside an air-conditioned office room at a set point temperature of 29 o C, involving three stages of fan configurations: Stage 1 No-fan, Stage 2 Single fan, and Stage 3 Dual fan.The overall measurement outcomes noted that different configurations of air direction from desk fans successfully improved the occupant's thermal comfort from slightly comfortable to moderately comfortable by reducing the thermal sensation to 50%.Additionally, the air directions from the front and head were most preferred.The air movement lowered the skin temperature from 0.7 to 0.9 o C.
DOI: 10.5109/7323403
Institutions: University of Technology Malaysia, Tokyo City University
Language: English
Subfield: Building and Construction
Field: Engineering
Domain: Physical Sciences
Open Access status: hybrid
Award: G1459609202
OpenAlex ID: W4404653543