Work

Early prediction of Li-ion cell failure from EIS derived from current–voltage time series

Year: 2024
Type: article
Abstract: The ability to reliably detect the forthcoming failure of a rechargeable cell without removing it from its normal operating environment remains a significant goal in battery research. In this work we have cycled in the laboratory a previously-aged 3.2 A h, 3.6 V 18650 INR LiNi x Mn y Co 1 − x − y O2 cell for 300 d until failure was apparent, using a current waveform representative of use in an electric vehicle application. Electrochemical impedance spectroscopy (EIS) down to 5 µHz was also performed on the cell as a ‘gold-standard’ measure, at the beginning, end and part way through the cycling. Analysis of voltage and current time series data using both parametric (equivalent circuit model) and non-parametric (wavelet-based analysis) approaches allowed us to successfully reconstruct the EIS data. As the battery aged, impedance gradually increased at frequencies between 10−4 Hz—10−1 Hz. The increase accelerated around 50 d before the battery ultimately failed. The acceleration in rate of change of impedance was detectable while the cycle efficiency remained high, indicating that a user of the cell would be unlikely to detect any change in the cell based on its performance or by common measures of state-of-health. The results imply upcoming failure may be detectable from time series analysis weeks before any noticeable drop in cell performance.
Language: English
Open Access status: gold
Estimated APC paid: $2,680
OpenAlex ID: W4404781344
FWCI: 0.215
Cites: 67
Cited by: 2
Related to: 10