Work

Long term performance of Nature-Based Solutions as decentralized wastewater treatment: a case study of a retail store in southern Italy

Year: 2024
Type: article
Abstract: The aim of this study is to evaluate the removal efficiency and the hydraulic behavior of the 10-year-old hybrid treatment wetland (TW) system treating effluents of the IKEA® store of Catania (Eastern Sicily, Italy), under Mediterranean semi-arid climate conditions. The system is placed downstream to the conventional wastewater (WW) treatment of the store, that includes a sequential batch reactor (SBR) followed by a horizontal subsurface treatment wetland (HF) unit and two vertical subsurface flow treatment wetlands (VF1 and VF2) units. The assessment of chemical, physical, and microbiological parameters in treated WW was carried out through regular monitoring activities, occurring approximately on a monthly basis, over a 8-year period spanning from 2016 to 2023. Up to 72 samples were collected for the following parameters measurements: total suspended solids (TSS), BOD 5 , COD, total phosphorus (TP), ammonia (as NH 4 ), nitrate (as NO 3 -N), nitrite (as NO 2 -N), total nitrogen (TN) and E. coli . Hydraulic conductivity at saturation ( K s ) measurements and tracer tests were conducted to evaluate the extent of clogging and to characterize the hydraulic behavior within the HF unit. Results obtained during the entire monitoring period show the following mean and standard errors (±) removal efficiency ranges (%): TN 21(±11)-80(±9); TSS 18(±42)-95(±3); COD 28(±23)-93(±2); BOD 5 31(±10)-85(±44); TP 14(±6)-49(±19); NH 4 50(±50)-95(±3); E. coli was abated with a mean range of 3.3(±0.2)-4.8(±0.4) Ulog reduction, reaching not detectable values in most samples analyzed since 2018. The efficacy of the treatment system is assessed in the context of both national and European regulatory frameworks governing effluent discharge and water reuse standards. K s values and tracer test results agree in showing the progressive clogging of the HF unit influencing the hydraulic behavior of the unit giving useful on the management of TWs in Mediterranean area. Finally, the performance results also indicate that the overall treatment is not affected by the HF unit clogging. • Clogging evolution may eventually result in ponding phenomena and sanitation risks. • In spite of the clogging occurrence TW effluent quality meets standard requirements. • A correct TW management allows safe toilet flushing and green areas irrigation reuse.
Language: English
Open Access status: hybrid
Estimated APC paid: $3,650
OpenAlex ID: W4404782845
FWCI: 0.261
Cites: 49
Cited by: 1
Related to: 10