Work

In-vehicle air quality in public buses during real-world trips in Kathmandu Valley, Nepal

Year: 2024
Type: article
Abstract: • Cabin air quality and ventilation rates in public buses were analyzed. • Both in-cabin and outdoor PM 2.5 concentrations were approximately 95 μg/m 3 . • In-cabin CO 2 concentrations ranged from 513 to 1230 ppm. • Cabin ventilation rates ranged from 8 to 72 L/s/person. • Implementing ventilation standards in public buses is crucial in Kathmandu. Urban air quality shows notable variability across various microenvironments. Transport-related microenvironments often have one of the highest air pollution levels, where commuters have significant exposure to air pollutants. In Kathmandu Valley (KV), Nepal, passengers’ exposure to air pollutants in such microenvironments remain a poorly understood issue. In this study, we analyzed cabin air quality and ventilation rates in public buses operated in KV. In-cabin and in-route ambient air pollution levels were monitored during real-world bus operations in 32 trips on a test route selected in the core city area. A CO 2 mass balance model was applied to estimate cabin ventilation rates. The mean in-cabin and outdoor PM 2.5 concentrations were 95.9 ± 40.4 (mean ± standard deviation) and 94.7 ± 32.4 μg/m 3 , respectively. Likewise, mean in-cabin and outdoor PM 1 concentrations were 72.5 ± 31.3 and 69.7 ± 25.3 μg/m 3 , respectively, with mean PM 1 to PM 2.5 ratio >0.75, indicating that a majority of particle mass was in the sub-micron size range, which is often more health-hazardous. We estimated passengers’ inhalation dose for PM 2.5 and PM 1 as 5.65 ± 2.32 and 4.27 ± 1.79 μg/km, respectively. Among various factors considered, traffic hour significantly affected both in-cabin and ambient particulate matter concentrations. The trip-average in-cabin CO 2 concentration ranged from 513 to 1230 ppm, whereas cabin ventilation rates ranged from 8.0 to 72.4 L/s/person. Ventilation levels in a majority of bus trips were inadequate, especially considering the recommended thresholds to reduce the transmission risk of airborne diseases. Setting standards for ventilation and air conditioning systems in public buses is crucial to ensure thermal comfort, protect bus commuters from the harmful impacts of air pollution, and to improve public transport services in KV.
Authors: Anu Shrestha, Narayan Babu Dhital
Language: English
Open Access status: gold
Estimated APC paid: $1,800
OpenAlex ID: W4404800606
FWCI: 1.125
Cites: 42
Cited by: 7
Related to: 10