(334) Early Mechanical Failure Is Rare but Auto Inflation Is Common After Penile Prosthesis Placement
Year: 2024
Type: article
Study design: Observational Study
Abstract: Introduction Penile prosthesis (PP) implantation is associated with high patient satisfaction in patients with medically refractory erectile dysfunction (ED). There remains a paucity in the literature regarding the temporal evolution of patient following PP surgery. Objective We sought to evaluate mechanical-associated outcomes in our Penile prosthesis (PP) cohort. Methods We analyzed our prospective penile registry that includes patient-completed surveys regarding device outcomes administered at 6 and 12-months after PP placement. We specifically examined the questions: “Have you had another [prosthesis] surgery since your first operation?”; and, “Does the device ever inflate or deflate on its own, if Yes how bothersome is this for you on a scale of 1-10 (1- very bothersome, 10 no bother)?”. Chart review was performed to identify pertinent variables including reservoir location (retropubic vs submuscular) and need for prosthesis revision for survey respondents. Results A total of 304 patients were enrolled in the registry. Of these, 101 completed the 6-month assessment and 79 completed the 1-year survey. The vast majority of PP were Coloplast (91.4%) utilizing the “classic” pump. Mean chart review follow up was approximately 3 years. One device was explanted for implant infection. No additional operations were reported for mechanical failure. Auto-inflation (AI) was reported in 38 patients at 6 months and 21 patients at 12 months. AI was most common in patients with submuscular reservoir placement (75.9% of those who reported AI at 6 months and 50% at 12 months respectively). The relative risk of developing AI was doubled in patients with a submuscular reservoir [2.2 (1.05-3.44); p < 0.001)]. Degree of bother had a reported median of 5 (3.75-9) at 6 months and became less bothersome after 12-months year with a reported median of 7 (5-9) (p = 0.230) [Fig. 1]. Conclusions Early Penile prosthesis mechanical failure requiring revision surgery did not occur in our cohort but patient-reported auto-inflation was identified more frequently than previously reported. Further study is warranted, but patients may benefit from pre-operative counseling regarding the incidence of auto-inflation. Disclosure Yes, this is sponsored by industry/sponsor: Coloplast. Clarification: Industry funding only - investigator initiated and executed study.
Source: The Journal of Sexual Medicine
Authors: M Ziegelmann, A Guillen, A Pinkhasov, M Bonakdarhashemi, S Helo, T Kohler
Institution: Mayo Clinic
Language: English
Subfield: Psychiatry and Mental health
Field: Medicine
Domain: Health Sciences
Open Access status: bronze
Funder: Coloplast
OpenAlex ID: W4405220743
