Year: 2024
Type: article
Abstract: The Joint Polar Satellite System 3 (JPSS-3) and 4 (JPSS-4) Visible Infrared Imaging Radiometer Suite (VIIRS) are the fourth and fifth in its series of instruments designed to provide high-quality data products for environmental and climate data records. The VIIRS instrument must be calibrated and characterized prior to launch to meet the data product needs. A comprehensive test program was conducted at the Raytheon Technologies facility in 2020 (JPSS-3) and 2023 (JPSS-4) that included extensive functional and environmental testing. The thermal band radiometric pre-launch performance and stability are the focus of this article, which also compares several instrument performance metrics to the design requirements. Brief comparisons with the JPSS-1 and -2 VIIRS instrument performance will also be discussed.
Source: Remote Sensing
DOI: 10.3390/rs16244630
Language: English
Subfield: Aerospace Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $3,069