Determination of the maximum suction height of the pumping unit (using the example of the pumping station in Dvin)
Year: 2024
Type: article
Abstract: The Dvin pumping station is designed for subsidized supply of up to 180 liters/s from Artashat Canal to Dvin Canal for the purpose of irrigation of lands under the Dvin Canal. The water supply from the channel to the receiving pool is carried out in a non-pressurized mode of movement through a concreted channel of rectangular cross-section of short length, the bottom of which is above the water level in the channel at a minimum depth of flow. The receiving pool communicates with the canal through a short pipe. Here the problem arises of determining the height of the maximum suction of the pumping unit. In this paper, it is solved using modern methods of mathematical measurements, which can be an exa
Author: Davit Madoyan
Language: English
Subfield: Civil and Structural Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: bronze
OpenAlex ID: W4405363732