Work

CMS improved Resistive Plate Chambers (iRPC) upgrade: Web-based automation for Quality Control

Year: 2024
Type: conference-paper
Abstract: In the context of the CMS improved Resistive Plate Chambers (iRPC) upgrade, we have developed a strategy that leverages cosmic muon triggers along with web-based automation for Quality Control (QC) steps. A key aspect of our approach was finding a way to bridge slow and fast control parameters, a crucial step towards achieving full automation. This integration not only enhances the efficiency and accuracy of the QC process for the iRPC system but also streamlines the workflow and significantly reduces the likelihood of human errors. This development is a valuable improvement in the CMS experiment's upgrade efforts, contributing to more reliable and efficient operations in high-energy physics research.
Authors: Ece Asilar, Mohammad Ahammad Ali, Kevin Mota, CMS MUON group
Institution: Hanyang University
Language: English
Open Access status: hybrid
OpenAlex ID: W4405596636
FWCI:
Cites: 2
Cited by:
Related to: 10