[Biomechanical study of screw implant angle in reconstruction of tibiofibular syndesmosis injury].
Year: 2024
Type: other
Abstract: Objective: To investigate ideal screw implant angle in reconstruction of tibiofibular syndesmosis injury by using a biomechanical test. Methods: A total of 24 ankle specimens from adult cadavers were used as the tibiofibular syndesmosis injury model. According to the angle of screw placement, the tibiofibular syndesmosis injury models were randomly divided into groups A (0°), B (10°-15°), C (20°-25°), and D (30°-35°), and the screws were placed at a level 2 cm proximal to the ankle joint. The displacement of fibula was measured by biomechanical testing machine at neutral, dorsiflexion (10°), plantar flexion (15°), varus (10°), and valgus (15°) positions, with axial load of 0-700 N (pressure separation test). The displacement of fibula was also measured at neutral position by applying 0-5 N·m torque load during internal and external rotation (torsional separation test). Results: >0.05). Conclusion: The ideal screw implant angle in reconstruction of tibiofibular syndesmosis injury was 20°-25°, which has a small displacement of fibula.
Source: PubMed
Language: English
Topic: Foot and Ankle Surgery
Subfield: Orthopedics and Sports Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W4405617840
